Citizen Cincom RS-232 Parameters

Citizen Cincom RS-232 Parameters

Controls

  1. Known to work on modern Citizen CINCOM controls
Notate or take a picture of any parameters before you change them

Change Citizen Parameters

  1. Put control in EDIT mode
  2. Press LIST softkey
  3. Press I/O softkey
  4. Press 232C Set softkey
  5. Input/Output Destination is "IC CARD R/W"
  6. Change the following parameters:
    1. Baud rate to "9600"
    2. Stop Bit to "2 Bit"
    3. Parity to "Even"
    4. Char Length to "7 Bits"
    5. HRDWRE Flow to "Invalid"
    6. XON/XOFF to "Valid"
    7. DC Code Out to "Output (DC3 output)"
    8. TV Check to "OFF"
    9. EOB Output to "CR LF"
    10. Feed No. to "10"
    11. Time-Out to "100"
    12. Time is in 1/10 seconds, i.e. 100 is 10 seconds)
    13. Data Code to "ISO"
    14. DC3 Code to "0x93"



    • Related Articles

    • How to Set Citizen Cincom Network Settings

      Controls Known to work on modern Citizen CINCOM controls Requirements Static IP address, subnet mask, and gateway Notate or take a picture of any parameters before you change them Enable Parameter Write Press MAINT. button Press I/F Diag softkey Type ...
    • Mazak Mazatrol 640 RS-232 Parameters

      Controls Mazatrol 640T, 640M Mazatrol 640T, 640M Nexus PC-Fusion-CNC Notate or take a picture of any parameters before you change them Set EIA (TAPE) Parameters Press far-left softkey Press DATA I/O Press TAPE Press PARAM. Set BAUDRATE to "19200" ...
    • Haas RS-232 Parameters

      Controls Any Haas with a RS-232 Port (usually 2016 or older, formally called Classic Haas Control or CHC) Notate or take a picture of any parameters before you change them Set Parameters Standard Transfers (Default) Press SETNG GRAPH button Press ...
    • Fanuc 16, 18, 21, 0i, 30i, 31i, 32i RS-232 Parameters

      Controls Fanuc 16-M, 16-T, 16i-M, 16i-T, 16i-MB, 16i-TB, 160i-MB, 160i-TB, 160is-MB, 160is-TB Fanuc 18-M, 18-T, 18i-M, 18i-T, 18i-MB, 18i-TB, 180i-MB, 180i-TB, 180is-MB, 180is-TB Fanuc 21-M, 21-T, 21i-M, 21i-T, 21i-MB, 21i-TB, 210i-MB, 210i-TB, ...
    • Siemens 802D RS-232 Parameters

      Controls Siemens 802D Notate or take a picture of any parameters before you change them Change Siemens 802D Parameters Press Menu Select button Press Services softkey Press Devices softkey Select Standard interface from top Press Copy to clipboard ...