Fanuc 10, 11, 12, & 15 RS-232 Parameters
Controls
- Fanuc 10M, 10T, 11M, 11T, 12M, 12T, 15M, 15T
Notate or take a picture of any parameters before you change them
Change Fanuc Parameters
- Set write key to enable
- Put control in MDI mode
- Press far left softkey until you see SETTING softkey
- Press SETTING softkey until you get to "SETTING(HANDY)" page
- Set the following settings
- PUNCH CODE to "0"
- INPUT DEVICE to "1" or "2"
- OUTPUT DEVICE to "1" or "2"

- 1 is MDI/CRT port of 10/11/12 controls. CD4A connector on the base 0 PCB of a 15 control
- 2 is Master PCB of 10/11/12 controls. CD4B connector on the base 0 PCB of a 15 control
- Press SETTING softkey until you get to "SETTING(SETTINGS)" page
- Press left cursor key to reveal parameter 8000 bit 0, change it to "1" to enable parameter write (PWE)
- Press right cursor to reveal parameter 0000 and set the following parameters
Double right and double left are page up and page down keys- 0000 to "00000000"
- 5001 to "1"
- 5002 to "1"
- 5110 to "3"
- 5111 to "2"
- 5112 to one of the following
- Set to "12" for 19200 baud
- Set to "11" for 9600 baud
- Set to "10" for 4800 baud
- Set to "9" for 2400 baud
- Set to "8" for 1200 baud
- Go back to parameter 8000 bit 0, change it to "0" to disable parameter write (PWE)