Fanuc 16, 18, 21, 0i, 30i, 31i, 32i RS-232 Parameters
Controls
- Fanuc 16-M, 16-T, 16i-M, 16i-T, 16i-MB, 16i-TB, 160i-MB, 160i-TB, 160is-MB, 160is-TB
- Fanuc 18-M, 18-T, 18i-M, 18i-T, 18i-MB, 18i-TB, 180i-MB, 180i-TB, 180is-MB, 180is-TB
- Fanuc 21-M, 21-T, 21i-M, 21i-T, 21i-MB, 21i-TB, 210i-MB, 210i-TB, 210is-MB, 210is-TB
- Fanuc 0i-M, 0i-T, 0i-MB, 0i-TB, 0i-MC, 0i-TC, 0i-MD, 0i-TD, 0i-MF, 0i-TF
- Fanuc 30i Model A, Model A5, Model B, Model B5
- Fanuc 31i Model A, Model A5, Model B, Model B5
- Fanuc 32i Model A, Model A5, Model B, Model B5
- Essentially any Fanuc control manufactured since the late 90s
Notate or take a picture of any parameters before you change them
Change Fanuc Parameters
- Put control in MDI mode
- Press OFFSET/SETTING (aka OFS/SET) button until you see the SETTING (HANDY) page
- If you do not see the SETTING (HANDY) page, either press the SETTING softkey or press OFFSET/SETTING until you do see it
- Set PARAMETER WRITE (PWE) to "1"
- Set PUNCH CODE or OUTPUT CODE to "1"
- Set I/O CHANNEL to "0"
- Press SYSTEM button
- Press PARAMETER softkey
- Set the following parameters
- 0000 to "XXXXXX10" ("X" means do not change)
- 0020 to "0"
- 0100 to "00000000"
- 0101 to "10000001"
- 0102 to "0"
- 0103 to one of the following:
- Set to "12" for 19200 baud
- Set to "11" for 9600 baud
- Set to "10" for 4800 baud
- Press OFFSET/SETTING button
- Set PARAMETER WRITE (PWE) to "0"
- Press RESET button to clear alarm
Related Articles
Haas RS-232 Parameters
Controls Any Haas with a RS-232 Port (usually 2016 or older, formally called Classic Haas Control or CHC) Notate or take a picture of any parameters before you change them Set Parameters Standard Transfers (Default) Press SETNG GRAPH button Press ...
Fanuc 10, 11, 12, & 15 RS-232 Parameters
Controls Fanuc 10M, 10T, 11M, 11T, 12M, 12T, 15M, 15T Notate or take a picture of any parameters before you change them Change Fanuc Parameters Set write key to enable Put control in MDI mode Press far left softkey until you see SETTING softkey Press ...
Siemens 802D RS-232 Parameters
Controls Siemens 802D Notate or take a picture of any parameters before you change them Change Siemens 802D Parameters Press Menu Select button Press Services softkey Press Devices softkey Select Standard interface from top Press Copy to clipboard ...
Okuma OSP P100, P200, P300 RS-232 Parameters
Controls OSP-P100L, OSP-P100M OSP-P200L, OSP-P200M, OSP-P200S, OSP-P200LA, OSP-P200MA, OSP-P200SA OSP-P300L, OSP-P300M, OSP-P300S, OSP-P300LA, OSP-P300MA, OSP-P300SA Notate or take a picture of any parameters before you change them Set Tape Puncher ...
Siemens 810D Powerline RS-232 Parameters
Controls Siemens 810D Powerline Notate or take a picture of any parameters before you change them Change Siemens 802D Parameters Press MENU SELECT button Press SERVICES Press SET Set the following parameters Interface to “COM1” Protocol to “XON/XOFF” ...