How to Configure Siemens 840D sl Network Settings
Overview
This article will review how to configure the Siemens 840D sl (Solution Line) network settings. This is also referred to as the Siemens 840D with Operate.
Requirements
- Network Drop
- Manufacturer Password
SFA Technical Support can provide this to customers with an active account or a support contract
Plug in Network Cable
- Typically located in the rear cabinet, locate the X130 port and plug in your Ethernet cable
Set Manufacturer Password
- Press MENU SELECT button
- Press Setup
- Press Pass-word
- Press Set password
- Type in the manufacturer password
- Press INPUT button
Choose either Method 1 or Method 2 based on what buttons and menus options you see
Set Network Settings (Method 1)
- Press MENU SELECT button
- Press Setup
- Press >
- Press Net-work
- Press Overview
- Press Change
Do not change System network, this will break your machine. - Under Company Network, change IP address and Subnet mask
- Press OK when done
- Reboot control
Set Network Settings (Method 2)
- Press MENU SELECT button
- Press Diag-nostics
- Press >
- Press Bus TCP/IP
- Press TCP/IP diagnost.
- Press TCP/IP config.
- Press Change
Do not change System Network (X120), this will break your machine. - Under NCU Company Network (X130 port), change IP address and Subnet mask
If there is no NCU, PCU can be used instead - Press OK when done
- Reboot control
Related Articles
How to Configure Fanuc Network and FOCAS Settings
Overview This article includes steps to configure network and FOCAS settings. Requirements Static IP Address, Subnet Mask, & Gateway Network Drop Preparation Plug network cable into CD38A port, this is typically located in the main electrical cabinet ...
How to Configure Haas NGC Network Settings
Overview This will go over how to configure the wired Ethernet settings and Net Share on a Haas Next Generation Control. Configure Wired Connection settings Press SETTING button Go to Network tab Go to Wired Connection tab To set the following ...
How to Set Citizen Cincom Network Settings
Controls Known to work on modern Citizen CINCOM controls Requirements Static IP address, subnet mask, and gateway Notate or take a picture of any parameters before you change them Enable Parameter Write Press MAINT. button Press I/F Diag softkey Type ...
How to Configure DMG Mori MAPPS Network Settings
Overview This article includes steps to configure network settings on a DMG Mori MAPPS control. Controls MAPPS III & IV Requirements Static IP Address, Subnet Mask, & Gateway Network Drop Preparation Plug into only one of the following network ports ...
Siemens 840D RS-232 Parameters
Controls Any Siemens SINUMERIK 840D w/ RS-232 Notate or take a picture of any parameters before you change them Set Parameters Press MENU SELECT button Press Services softkey Press Interface softkey Press RS232C softkey (on the right) to get to the ...