How to Enable Parentheses on Fanuc

How to Enable Parentheses on Fanuc

Overview

Some Fanuc controls do not have enough keys and will omit the parentheses. There is a parameter to show the C-EXT softkey that contains special characters which includes parentheses. This is known to work on Fanuc 16, 18, and all i-Series.

Enable C-EXT Softkey

  1. Change Parameter 3204 bit 2
    1. 0 will disable C-EXT softkey (XXXXX0XX)
    2. 1 will enable C-EXT softkey (XXXXX1XX)


    • Related Articles

    • How to Enable DHCP on a Fanuc

      To enable DHCP on a Fanuc that does not show the option in the COMMON settings page, set parameter # 14880 bit 6 to 1 (bits are read from right to left, starting with 0 on the right and 7 on the left), then restart the control. Ensure the Ethernet ...
    • NC Program Format - Fanuc

      Overview The following is how a Fanuc program is formatted. This provides no guidance on G and M code, only format. Program Naming O number, e.g. O1234 This is the most common Numeric only Can be called by M98 Leading zeros are not necessary, e.g. ...
    • How to Edit Fanuc 8000 & 9000 Programs

      Overview By default, 8000 and 9000 programs are protected and cannot be edited. Enabling a parameter is required to edit 8000 and 9000 programs. It is absolutely critical you know what you are doing when working with 8000 and 9000 programs. Changing ...
    • How to Configure Fanuc FTP Settings

      Overview The article provides instructions on configuring FTP and establishing the correct I/O channel for transferring data to and from an FTP server. Here, the CNC machine functions as the FTP client. Requirements CNC Connected to Network (How to ...
    • Fanuc 10, 11, 12, & 15 RS-232 Parameters

      Controls Fanuc 10M, 10T, 11M, 11T, 12M, 12T, 15M, 15T Notate or take a picture of any parameters before you change them Change Fanuc Parameters Set write key to enable Put control in MDI mode Press far left softkey until you see SETTING softkey Press ...