How to Obtain Mitsubishi EDM Version Information to Get MTConnect

How to Obtain Mitsubishi EDM Version Information to Get MTConnect

Overview

To obtain a MTConnect Adapter for Mitsubishi EDMs, it is necessary to gather the main system version number as well as check if it has the DNC option. This article will provide instructions on how to obtain this information so you can provide it to your Account Executive. 

Determine Software Version Number

  1. Navigate to MAINT softkey at the top, then click on the clock softkey on the right, then press VERSION
  2. Note version number for “MAIN SYSTEM”

Determine whether DNC option is installed

  1. Navigate to MAINT softkey at the top
  2. Hold Ctrl + Shift then right-click on Tools (next to M7 or M8 button)
  3. Pop-up menu will appear
  4. Activate both User Maintenance and Maker Maintenance
  5. Go to Parameters
  6. Open Options
  7. This area will display all HW and SW options (will show checkmark if active)
  8. Please note whether the DNC option is checked or not


    • Related Articles

    • How to Check if a DMG Mori has an MTConnect Adapter

      Overview Since around 2013, DMG Mori machines (previously known as Mori Seiki) have been equipped with MTConnect as a standard feature, although this is restricted to Fanuc and Mitsubishi back-ends. Machines from earlier years might also support ...
    • How to Check Siemens 840D HMI Version

      Overview This article will review how to determine which version of SINUMERIK 840D HMI Version is running. It is best to take pictures, so all data is captured accurately. Checking HMI Version on HMI Advanced (older control) Actual steps may vary, ...
    • Why does my Fanuc give "The Wrong Data is Used" error message?

      Problem When trying to send, punch, or output a program, the Fanuc give an error "The Wrong Data is Used". Reason This is a syntax error and most likely due to how the program name or number is being typed. In some cases, this is also due to the ...
    • Okuma OSP 5000M-G, 5020M, 700M, 7000M RS-232 Parameters

      Controls OSP5000M-G OSP5020M OSP700M OSP7000M Notate or take a picture of any parameters before you change them Change Okuma Parameters Ensure the NC PANEL key is set to "UNLOCK" Press PARAMETER button Press ITEM DOWN (F7) softkey until you get to ...
    • Okuma OSP 5000L-G, 5020, 5020L, 700L, 7000L RS-232 Parameters

      Controls OSP5000L-G OSP5020 OSP5020L OSP700L OSP7000L Notate or take a picture of any parameters before you change them Change Okuma Parameters Ensure the NC PANEL key is set to "UNLOCK" Press PARAMETER button Press ITEM DOWN (F7) softkey until you ...