How to Obtain Required Information for Siemens 840D HMI Advanced MTConnect Adapter

How to Obtain Required Information for Siemens 840D HMI Advanced MTConnect Adapter

Overview

Some details are needed to create an MTConnect Adapter for Siemens 840D HMI Advanced controls. 

Obtain HMI Version

Info
Recommend taking pictures of requested screens to avoid any typos. 
  1. Press Menu Select
  2. Press Diagnosis
  3. Press Service Displays
  4. Press Version
    1. On "NCU Version" page, notate the numbers under "Version Data NCU" (e.g. 06.05.39)
    2. On "HMI Version" page, notate the HMI System Software (record the entire HMI Version number)

Obtain MAC Address

Enter Password

Info
This step is only needed if control is not in manufacture mode; if in doubt, proceed to set the password
  1. Press Menu Select
  2. Press Start-up
  3. Press Password...
  4. Press Set password
  5. Enter "SUNRISE" as the password

Open DOS Shell (Command Prompt) and Find MAC Address

  1. Press Menu Select
  2. Press MMC or HMI, whichever appears
  3. Press DOS Shell
  4. In the DOS shell window, type "ipconfig /all"
  5. Notate the "IP Address" and "Physical Address" (i.e. MAC address)

Clear Password

Info
This step is only needed if control was not in manufacture mode; if in doubt, proceed to clear password
Info
Clearing password does not "delete" it contrary to Siemens terminology, it only put the control back into operator mode
  1. Press Menu Select
  2. Press Start-up
  3. Press Password...
  4. Press Delete password 

Provide Information to SFA

  1. Send requested information to your Account Executive or to support@shopfloorautomations.com
    • Related Articles

    • How to Use Okuma SCOUT to Determine MTConnect Version & Compatibility

      Overview This guide will take you through the steps to see if your P series Okuma CNC is compatible with MTConnect Requirements Setup a free Okuma Account (found at www.myokuma.com) SCOUT app (found at www.myokuma.com) USB Flash Drive Optional: USB ...
    • How to Check for MTConnect on Siemens 840D

      Press Menu Select or Menu Function button Press far right softkey until you find a box at the bottom called "MTConnect" If the MTConnect button is shown, it's installed If it is not shown, it will need to be purchased from SFA and/or installed by a ...
    • Why are most Okuma MTConnect tags UNAVAILABLE

      Problem The MTConnect Agent on the Okuma control appears to be working, but most tags are UNAVAILABLE Reason Upon installation of the MTConnect Adapter, the Enable Monitoring Tags checkbox was not checked Solution Open the MTConnect Adapter, go to ...
    • MTConnect Execution Values

      The following are the values produced by the Execution tag. The values are shown in their standard form and only applicable to v1.3 or newer. READY The controller is ready to execute instructions. It is currently idle. ACTIVE The controller is ...
    • How to install .NET 3.5 if PC is Unable to Download or Find Resource Files

      Open an elevated (administrator) command prompt and run the following: DISM.EXE /Online /Add-Package /PackagePath:C:\Features\Microsoft-Windows-NetFx3-OnDemand-Package.cab Adjust the above command to wherever your CAB file for the .NET 3.5 package is ...