How to Set Citizen Cincom Parameters

How to Set Citizen Cincom Parameters

Controls

  1. Known to work on modern Citizen CINCOM controls
Notate or take a picture of any parameters before you change them

Change Citizen Parameters

  1. Put control in EDIT mode
  2. Press LIST softkey
  3. Press I/O softkey
  4. Press 232C Set softkey
  5. Input/Output Destination is "IC CARD R/W"
  6. Change the following parameters:
    1. Baud rate to "9600"
    2. Stop Bit to "2 Bit"
    3. Parity to "Even"
    4. Char Length to "7 Bits"
    5. HRDWRE Flow to "Invalid"
    6. XON/XOFF to "Valid"
    7. DC Code Out to "Output (DC3 output)"
    8. TV Check to "OFF"
    9. EOB Output to "CR LF"
    10. Feed No. to "10"
    11. Time-Out to "100"
    12. Time is in 1/10 seconds, i.e. 100 is 10 seconds)
    13. Data Code to "ISO"
    14. DC3 Code to "0x93"



    • Related Articles

    • How to Set Citizen Cincom Network Settings

      Controls Known to work on modern Citizen CINCOM controls Requirements Static IP address, subnet mask, and gateway Notate or take a picture of any parameters before you change them Enable Parameter Write Press MAINT. button Press I/F Diag softkey Type ...
    • How to Set Mazak Mazatrol 640 Parameters

      Controls Mazatrol 640T, 640M Mazatrol 640T, 640M Nexus PC-Fusion-CNC Notate or take a picture of any parameters before you change them Set EIA (TAPE) Parameters Press far-left softkey Press DATA I/O Press TAPE Press PARAM. Set BAUDRATE to "19200" ...
    • How to Set Fanuc RS-232 Parameters - 16, 18, 21, 0i, 30i, 31i, 32i

      Controls Fanuc 16-M, 16-T, 16i-M, 16i-T, 16i-MB, 16i-TB, 160i-MB, 160i-TB, 160is-MB, 160is-TB Fanuc 18-M, 18-T, 18i-M, 18i-T, 18i-MB, 18i-TB, 180i-MB, 180i-TB, 180is-MB, 180is-TB Fanuc 21-M, 21-T, 21i-M, 21i-T, 21i-MB, 21i-TB, 210i-MB, 210i-TB, ...
    • How to Set Fadal RS-232 Parameters

      Controls All Fadal Controls Notate or take a picture of any parameters before you change them Set Parameters Press MANUAL button until you see “ENTER NEXT COMMAND <” Type “SETP” and press ENTER button Press ENTER button to keep G-code style setting ...
    • How to Set Siemens 810D Powerline Parameters

      Controls Siemens 810D Powerline Notate or take a picture of any parameters before you change them Change Siemens 802D Parameters Press MENU SELECT button Press SERVICES Press SET Set the following parameters Interface to “COM1” Protocol to “XON/XOFF” ...