How to Set Fadal RS-232 Parameters

How to Set Fadal RS-232 Parameters

Controls

  1. All Fadal Controls
Notate or take a picture of any parameters before you change them

Set Parameters

  1. Press MANUAL button until you see “ENTER NEXT COMMAND <”
  2. Type “SETP” and press ENTER button
  3. Press ENTER button to keep G-code style setting
  4. Set baud rate using one of the following values
    1. 6 = 2400
    2. 7 = 4800
    3. 8 = 9600
    4. 9 = 19200
    5. 10 = 38400
  5. Press ENTER button
  6. Press MANUAL button to exit parameters
  7. Turn off main power for 5 minutes, then turn back on
  8. Parameters have now been set

    • Related Articles

    • How to Set Haas RS-232 Parameters

      Controls All Haas prior to 2016 Any Haas 2016 or later with an RS-232 interface Notate or take a picture of any parameters before you change them Set Parameters Standard Transfers (Default) Press SETNG GRAPH button Press Page Down button until you ...
    • How to Set Okuma P Series Parameters

      Controls OSP-P100L, OSP-P100M OSP-P200L, OSP-P200M, OSP-P200S, OSP-P200LA, OSP-P200MA, OSP-P200SA OSP-P300L, OSP-P300M, OSP-P300S, OSP-P300LA, OSP-P300MA, OSP-P300SA Notate or take a picture of any parameters before you change them Set Tape Puncher ...
    • How to Set Fanuc 10, 11, 12, & 15 RS-232 Parameters

      Controls Fanuc 10M, 10T, 11M, 11T, 12M, 12T, 15M, 15T Notate or take a picture of any parameters before you change them Change Fanuc Parameters Set write key to enable Put control in MDI mode Press far left softkey until you see SETTING softkey Press ...
    • How to Set Fanuc RS-232 Parameters - 16, 18, 21, 0i, 30i, 31i, 32i

      Controls Fanuc 16-M, 16-T, 16i-M, 16i-T, 16i-MB, 16i-TB, 160i-MB, 160i-TB, 160is-MB, 160is-TB Fanuc 18-M, 18-T, 18i-M, 18i-T, 18i-MB, 18i-TB, 180i-MB, 180i-TB, 180is-MB, 180is-TB Fanuc 21-M, 21-T, 21i-M, 21i-T, 21i-MB, 21i-TB, 210i-MB, 210i-TB, ...
    • How to Set Siemens 810D Powerline Parameters

      Controls Siemens 810D Powerline Notate or take a picture of any parameters before you change them Change Siemens 802D Parameters Press MENU SELECT button Press SERVICES Press SET Set the following parameters Interface to “COM1” Protocol to “XON/XOFF” ...