How to Set Fanuc 10, 11, 12, & 15 RS-232 Parameters

How to Set Fanuc 10, 11, 12, & 15 RS-232 Parameters

Controls

  1. Fanuc 10M, 10T, 11M, 11T, 12M, 12T, 15M, 15T
Notate or take a picture of any parameters before you change them

Change Fanuc Parameters

  1. Set write key to enable
  2. Put control in MDI mode
  3. Press far left softkey until you see SETTING softkey
  4. Press SETTING softkey until you get to "SETTING(HANDY)" page
    1. Set the following settings
      1. PUNCH CODE to "0"
      2. INPUT DEVICE to "1" or "2"
      3. OUTPUT DEVICE to "1" or "2"
        1. 1 is MDI/CRT port of 10/11/12 controls. CD4A connector on the base 0 PCB of a 15 control
        2. 2 is Master PCB of 10/11/12 controls. CD4B connector on the base 0 PCB of a 15 control
    2. Press SETTING softkey until you get to "SETTING(SETTINGS)" page
    3. Press left cursor key to reveal parameter 8000 bit 0, change it to "1" to enable parameter write (PWE)
    4. Press right cursor to reveal parameter 0000 and set the following parameters
      1. Double right and double left are page up and page down keys
      2. 0000 to "00000000"
      3. 5001 to "1"
      4. 5002 to "1"
      5. 5110 to "3"
      6. 5111 to "2"
      7. 5112 to one of the following
        1. Set to "12" for 19200 baud
        2. Set to "11" for 9600 baud
        3. Set to "10" for 4800 baud
        4. Set to "9" for 2400 baud
        5. Set to "8" for 1200 baud
    5. Go back to parameter 8000 bit 0, change it to "0" to disable parameter write (PWE)



      • Related Articles

      • How to Set Haas RS-232 Parameters

        Controls All Haas prior to 2016 Any Haas 2016 or later with an RS-232 interface Notate or take a picture of any parameters before you change them Set Parameters Standard Transfers (Default) Press SETNG GRAPH button Press Page Down button until you ...
      • How to Set Fanuc RS-232 Parameters - 16, 18, 21, 0i, 30i, 31i, 32i

        Controls Fanuc 16-M, 16-T, 16i-M, 16i-T, 16i-MB, 16i-TB, 160i-MB, 160i-TB, 160is-MB, 160is-TB Fanuc 18-M, 18-T, 18i-M, 18i-T, 18i-MB, 18i-TB, 180i-MB, 180i-TB, 180is-MB, 180is-TB Fanuc 21-M, 21-T, 21i-M, 21i-T, 21i-MB, 21i-TB, 210i-MB, 210i-TB, ...
      • How to Set Fadal RS-232 Parameters

        Controls All Fadal Controls Notate or take a picture of any parameters before you change them Set Parameters Press MANUAL button until you see “ENTER NEXT COMMAND <” Type “SETP” and press ENTER button Press ENTER button to keep G-code style setting ...
      • How to Set Okuma P Series Parameters

        Controls OSP-P100L, OSP-P100M OSP-P200L, OSP-P200M, OSP-P200S, OSP-P200LA, OSP-P200MA, OSP-P200SA OSP-P300L, OSP-P300M, OSP-P300S, OSP-P300LA, OSP-P300MA, OSP-P300SA Notate or take a picture of any parameters before you change them Set Tape Puncher ...
      • How to Set Siemens 810D Powerline Parameters

        Controls Siemens 810D Powerline Notate or take a picture of any parameters before you change them Change Siemens 802D Parameters Press MENU SELECT button Press SERVICES Press SET Set the following parameters Interface to “COM1” Protocol to “XON/XOFF” ...