How to Set Fanuc RS-232 Parameters - 16, 18, 21, 0i, 30i, 31i, 32i

How to Set Fanuc RS-232 Parameters - 16, 18, 21, 0i, 30i, 31i, 32i

Controls

  1. Fanuc 16-M, 16-T, 16i-M, 16i-T, 16i-MB, 16i-TB, 160i-MB, 160i-TB, 160is-MB, 160is-TB
  2. Fanuc 18-M, 18-T, 18i-M, 18i-T, 18i-MB, 18i-TB, 180i-MB, 180i-TB, 180is-MB, 180is-TB
  3. Fanuc 21-M, 21-T, 21i-M, 21i-T, 21i-MB, 21i-TB, 210i-MB, 210i-TB, 210is-MB, 210is-TB
  4. Fanuc 0i-M, 0i-T, 0i-MB, 0i-TB, 0i-MC, 0i-TC, 0i-MD, 0i-TD, 0i-MF, 0i-TF
  5. Fanuc 30i Model A, Model A5, Model B, Model B5
  6. Fanuc 31i Model A, Model A5, Model B, Model B5
  7. Fanuc 32i Model A, Model A5, Model B, Model B5
  8. Essentially any Fanuc control manufactured since the late 90s
Notate or take a picture of any parameters before you change them

Change Fanuc Parameters

  1. Put control in MDI mode
  2. Press OFFSET/SETTING (aka OFS/SET) button until you see the SETTING (HANDY) page
    1. If you do not see the SETTING (HANDY) page, either press the SETTING softkey or press OFFSET/SETTING until you do see it
  3. Set PARAMETER WRITE (PWE) to "1"
  4. Set PUNCH CODE or OUTPUT CODE to "1"
  5. Set I/O CHANNEL to "0"
  6. Press SYSTEM button
  7. Press PARAMETER softkey
  8. Set the following parameters
    1. 0000 to "XXXXXX10" ("X" means do not change)
    2. 0020 to "0"
    3. 0100 to "00000000"
    4. 0101 to "10000001"
    5. 0102 to "0"
    6. 0103 to one of the following:
      1. Set to "12" for 19200 baud
      2. Set to "11" for 9600 baud
      3. Set to "10" for 4800 baud
  9. Press OFFSET/SETTING button
  10. Set PARAMETER WRITE (PWE) to "0"
  11. Press RESET button to clear alarm



    • Related Articles

    • How to Set Haas RS-232 Parameters

      Controls All Haas prior to 2016 Any Haas 2016 or later with an RS-232 interface Notate or take a picture of any parameters before you change them Set Parameters Standard Transfers (Default) Press SETNG GRAPH button Press Page Down button until you ...
    • How to Set Fanuc 10, 11, 12, & 15 RS-232 Parameters

      Controls Fanuc 10M, 10T, 11M, 11T, 12M, 12T, 15M, 15T Notate or take a picture of any parameters before you change them Change Fanuc Parameters Set write key to enable Put control in MDI mode Press far left softkey until you see SETTING softkey Press ...
    • How to Set Fadal RS-232 Parameters

      Controls All Fadal Controls Notate or take a picture of any parameters before you change them Set Parameters Press MANUAL button until you see “ENTER NEXT COMMAND <” Type “SETP” and press ENTER button Press ENTER button to keep G-code style setting ...
    • How to Set Okuma P Series Parameters

      Controls OSP-P100L, OSP-P100M OSP-P200L, OSP-P200M, OSP-P200S, OSP-P200LA, OSP-P200MA, OSP-P200SA OSP-P300L, OSP-P300M, OSP-P300S, OSP-P300LA, OSP-P300MA, OSP-P300SA Notate or take a picture of any parameters before you change them Set Tape Puncher ...
    • How to Set Siemens 810D Powerline Parameters

      Controls Siemens 810D Powerline Notate or take a picture of any parameters before you change them Change Siemens 802D Parameters Press MENU SELECT button Press SERVICES Press SET Set the following parameters Interface to “COM1” Protocol to “XON/XOFF” ...