How to Set Siemens 810D Powerline Parameters
Controls
- Siemens 810D Powerline
Notate or take a picture of any parameters before you change them
Change Siemens 802D Parameters
- Press MENU SELECT button
- Press SERVICES
- Press SET
- Set the following parameters
- Interface to “COM1”
- Protocol to “XON/XOFF”
- Baud Rate to “9600”
- Data Bits to “7”
- Parity to “even”
- Stop Bits to “2”
- XON (hex) to “17”
- XOFF (hex) to “19”
- End of transfer to “1a”
- Check “Stop with EOT character”
- Press Save Settings
Related Articles
How to Set Haas RS-232 Parameters
Controls All Haas prior to 2016 Any Haas 2016 or later with an RS-232 interface Notate or take a picture of any parameters before you change them Set Parameters Standard Transfers (Default) Press SETNG GRAPH button Press Page Down button until you ...
How to Set Fadal RS-232 Parameters
Controls All Fadal Controls Notate or take a picture of any parameters before you change them Set Parameters Press MANUAL button until you see “ENTER NEXT COMMAND <” Type “SETP” and press ENTER button Press ENTER button to keep G-code style setting ...
How to Set Siemens 802D Parameters
Controls Siemens 802D Notate or take a picture of any parameters before you change them Change Siemens 802D Parameters Press Menu Select button Press Services softkey Press Devices softkey Select Standard interface from top Press Copy to clipboard ...
How to Set Okuma P Series Parameters
Controls OSP-P100L, OSP-P100M OSP-P200L, OSP-P200M, OSP-P200S, OSP-P200LA, OSP-P200MA, OSP-P200SA OSP-P300L, OSP-P300M, OSP-P300S, OSP-P300LA, OSP-P300MA, OSP-P300SA Notate or take a picture of any parameters before you change them Set Tape Puncher ...
How to Set Fanuc 10, 11, 12, & 15 RS-232 Parameters
Controls Fanuc 10M, 10T, 11M, 11T, 12M, 12T, 15M, 15T Notate or take a picture of any parameters before you change them Change Fanuc Parameters Set write key to enable Put control in MDI mode Press far left softkey until you see SETTING softkey Press ...