How to use a floppy emulator on a Mazak 640
Formatting
the USB stick (if needed):
Note: This must be done before using the floppy drive.
1. Plug in USB stick
2. Red light on floppy begins to flash
3. Press “
RES”
(reset button)
4. Red light on floppy will stop flashing
5. Press “
DATA IN/OUT”
softkey
6. Press “FLOPPY”
7. Press “FD FORMAT”
8. Enter -9999
then press Input
9. Press “START”
softkey
10. USB will now be formatted
Send to CNC:
1. Plug in USB stick
2. Red light on floppy begins to flash
3. Press “RES”
(reset button)
4. Red light on floppy will stop flashing
5. Press “DATA IN/OUT”
softkey
6. Press “FLOPPY”
softkey
7. Press “DIR.
SELECT” softkey
8. Select the folder your programs are stored in
and press Input
9. Press “CONTENTS
FD” softkey
10. Press “START”
softkey
11. Press “LOAD NC
<- FD” softkey
12. Press “START”
softkey
13. Program(s) will now be loaded into the main
memory
Receive from
CNC:1. Plug in USB stick
2. Red light on floppy begins to flash
3. Press “
RES”
(reset button)
4. Red light on floppy will stop flashing
5. Press “DATA IN/OUT”
softkey
6. Press “FLOPPY”
softkey
7. Press “DIR.
SELECT” softkey
8. Select the folder you want to save files to, then
press Input
9. Press “CONTENTS
FD” softkey
10. Press “START”
softkey
11. Press “SAVE NC ->
FD” softkey
12. Press “PROGRAM
FILE” softkey
13. Type in the program(s) you wish to save and
press Input (each time if more than 1
program)
14. Press “START”
softkey
15. Program(s) will now be saved onto the USB stick
Related Articles
Floppy Connect Emulator Installation Guide for Universal Model
Overview The Floppy Connect Emulator emulates your existing floppy drive & acts as if it were never removed. Works with almost any existing 720KB/1.44MB capacity DOS format floppy drive. 28 or 32 pin ribbon cables systems are supported & will connect ...
How to Format USB Drive for use with Mazak and Floppy Emulator Connect
Overview Mazaks require a special formatting on floppy disks to function so the same will hold true when using our Floppy Emulator Connect. Formatting the USB Drive Plug in USB drive into the Floppy Emulator Connect Red light on Floppy Emulator ...
Floppy Connect Emulator Installation Guide for Haas Model
Overview The Floppy Connect Emulator emulates your existing floppy drive & acts as if it were never removed. This article is for the Haas model only. USB Flash Drive Requirements We recommend using the included SFA USB flash drive. USB drive must be ...
Floppy Connect Emulator Installation Guide for IBM Model
Overview The Floppy Connect Emulator emulates your existing floppy drive & acts as if it were never removed. Works with almost any existing 720KB/1.44MB capacity DOS format floppy drive. 28 or 32 pin ribbon cables systems are supported & will connect ...
LED Status Lights on the Floppy Connect Emulator
Green LED Status Light The green light indicates a floppy read or write operation has been done. No green light at all, or solid green light, indicates a problem. Red LED Status Light The red light indicates that the USB drive is inserted. The red ...