Siemens 802D RS-232 Parameters
Controls
- Siemens 802D
Notate or take a picture of any parameters before you change them
Change Siemens 802D Parameters
- Press Menu Select button
- Press Services softkey
- Press Devices softkey
- Select Standard interface from top
- Press Copy to clipboard softkey
- Press Up/Left Diagonal button to go to the bottom
- Press Paste from clipboard softkey
- Give it a name, e.g. "Predator"
- Press Input button
- Press OK softkey
- Highlight the interface
- Press Edit softkey
- Edit the following settings
- Device type to "Universal"
- Protocol to "RTS/CTS"
- Baud rate to "4800"
- Stop bits to "2"
- Parity to "Even"
- Bits per character to "7"
- XON char. (hex) to "11"
- XOFF char. (hex) to "13"
- End of transmission ch. (hex) to "03"
- Leader, trailer to "no"
- Ready to "Yes"
- Stop at to "End char."
- End of block to "CRLF"
- Beginning of output after XON to "no"
- Timeout in sec. to "60"
- Transmission format to "Punch tape format"
- Press store softkey when done
- Highlight the interface
- Press Selection softkey
Related Articles
Siemens 810D Powerline RS-232 Parameters
Controls Siemens 810D Powerline Notate or take a picture of any parameters before you change them Change Siemens 802D Parameters Press MENU SELECT button Press SERVICES Press SET Set the following parameters Interface to “COM1” Protocol to “XON/XOFF” ...
Yasnac i80 RS-232 Parameters
Control Yasnac i80 Notate or take a picture of any parameters before you change them Change Yasnac Parameters Press PROG key Press far right UP/DOWN softkey to select top row of softkeys (indicated by outlines) Press IN/OUT softkey Press RS232C ...
Fanuc 0 RS-232 Parameters
Controls Fanuc 0M, 0T Notate or take a picture of any parameters before you change them Change Fanuc Parameters Put control in MDI mode Press DGNOS PARAM button until you see "PARAMETER" page Press PARAM softkey On SETTING 1 page, change the ...
Fadal CNC 88HS RS-232 Parameters
Controls All Fadal Controls Notate or take a picture of any parameters before you change them Set Parameters Press MANUAL button until you see “ENTER NEXT COMMAND <” Type “SETP” and press ENTER button Press ENTER button to keep G-code style setting ...
Parameters - Haas Classic Control
Controls Any Haas with a RS-232 Port (usually 2016 or older, formally called Classic Haas Control or CHC) Notate or take a picture of any parameters before you change them Set Parameters Standard Transfers (Default) Press SETNG GRAPH button Press ...