Siemens 802D RS-232 Parameters
Controls
- Siemens 802D
Notate or take a picture of any parameters before you change them
Change Siemens 802D Parameters
- Press Menu Select button
- Press Services softkey
- Press Devices softkey
- Select Standard interface from top
- Press Copy to clipboard softkey
- Press Up/Left Diagonal button to go to the bottom
- Press Paste from clipboard softkey
- Give it a name, e.g. "Predator"
- Press Input button
- Press OK softkey
- Highlight the interface
- Press Edit softkey
- Edit the following settings
- Device type to "Universal"
- Protocol to "RTS/CTS"
- Baud rate to "4800"
- Stop bits to "2"
- Parity to "Even"
- Bits per character to "7"
- XON char. (hex) to "11"
- XOFF char. (hex) to "13"
- End of transmission ch. (hex) to "03"
- Leader, trailer to "no"
- Ready to "Yes"
- Stop at to "End char."
- End of block to "CRLF"
- Beginning of output after XON to "no"
- Timeout in sec. to "60"
- Transmission format to "Punch tape format"
- Press store softkey when done
- Highlight the interface
- Press Selection softkey