Siemens 840D RS-232 Parameters

Siemens 840D RS-232 Parameters

Controls

  1. Any Siemens SINUMERIK 840D w/ RS-232
Notate or take a picture of any parameters before you change them

Set Parameters

  1. Press MENU SELECT button
  2. Press Services softkey
  3. Press Interface softkey
  4. Press RS232C softkey (on the right) to get to the "Interface: V24 (RS232)" page
  5. Set "Interface" to "COM1" or "COM2" to match the COM Port you're using
  6. Set "Protocol to "Xon/Xoff"
    1. Check "Send XON at Start Data on"
    2. Check "Stop with EOT character"
    3. Set "End of transmis. (hex)" to "03"
  7. Set "Parity" to "None"
  8. Set "Stop bits" to "1"
  9. Set "Data bits" to "8 bit"
  10. Set "Baud rate" to "9600" (feel free to select another speed)
  11. Set "Arch. format" to "Punch tape only with LF"
  12. Set "Timeout (sec)" to "30" 
  13. Press OK softkey (on the right)
Your PC settings will be 7 data bits, even parity, and 2 stop bits


    • Related Articles

    • Siemens 802D RS-232 Parameters

      Controls Siemens 802D Notate or take a picture of any parameters before you change them Change Siemens 802D Parameters Press Menu Select button Press Services softkey Press Devices softkey Select Standard interface from top Press Copy to clipboard ...
    • Siemens 810D Powerline RS-232 Parameters

      Controls Siemens 810D Powerline Notate or take a picture of any parameters before you change them Change Siemens 802D Parameters Press MENU SELECT button Press SERVICES Press SET Set the following parameters Interface to “COM1” Protocol to “XON/XOFF” ...
    • Haas RS-232 Parameters

      Controls Any Haas with a RS-232 Port (usually 2016 or older, formally called Classic Haas Control or CHC) Notate or take a picture of any parameters before you change them Set Parameters Standard Transfers (Default) Press SETNG GRAPH button Press ...
    • Okuma OSP P100, P200, P300 RS-232 Parameters

      Controls OSP-P100L, OSP-P100M OSP-P200L, OSP-P200M, OSP-P200S, OSP-P200LA, OSP-P200MA, OSP-P200SA OSP-P300L, OSP-P300M, OSP-P300S, OSP-P300LA, OSP-P300MA, OSP-P300SA Notate or take a picture of any parameters before you change them Set Tape Puncher ...
    • Fadal CNC 88HS RS-232 Parameters

      Controls All Fadal Controls Notate or take a picture of any parameters before you change them Set Parameters Press MANUAL button until you see “ENTER NEXT COMMAND <” Type “SETP” and press ENTER button Press ENTER button to keep G-code style setting ...