What causes a Mazak parity error?

What causes a Mazak parity error?

Problem

When parameters match on the Mazak and PC/USB, the machine is getting a parity H or set new paper tape error. 

Reason

When transferring EIA (i.e. Tape, G-Code) programs in and out of a Mazak, the data, parity, and stop bit should mismatch. 

Solution

Machine should be 8 None 1 or sometimes 8 None 2 while the computer should be 7 Even 2. 
    • Related Articles

    • Mazak Mazatrol 640 RS-232 Parameters

      Controls Mazatrol 640T, 640M Mazatrol 640T, 640M Nexus PC-Fusion-CNC Notate or take a picture of any parameters before you change them Set EIA (TAPE) Parameters Press far-left softkey Press DATA I/O Press TAPE Press PARAM. Set BAUDRATE to "19200" ...
    • How to Access Windows on Mazak Smooth

      Overview Accessing Windows on a Mazak Smooth control (windows-based) is necessary to set network settings, configure MTConnect, and setting up shares. Requirements Windows-based Smooth Control Accessing Windows Press the far-left softkey to reveal ...
    • Why does my Fanuc give "The Wrong Data is Used" error message?

      Problem When trying to send, punch, or output a program, the Fanuc give an error "The Wrong Data is Used". Reason This is a syntax error and most likely due to how the program name or number is being typed. In some cases, this is also due to the ...
    • Fanuc 16, 18, 21, 0i, 30i, 31i, 32i RS-232 Parameters

      Controls Fanuc 16-M, 16-T, 16i-M, 16i-T, 16i-MB, 16i-TB, 160i-MB, 160i-TB, 160is-MB, 160is-TB Fanuc 18-M, 18-T, 18i-M, 18i-T, 18i-MB, 18i-TB, 180i-MB, 180i-TB, 180is-MB, 180is-TB Fanuc 21-M, 21-T, 21i-M, 21i-T, 21i-MB, 21i-TB, 210i-MB, 210i-TB, ...
    • How to Edit Fanuc 8000 & 9000 Programs

      Overview By default, 8000 and 9000 programs are protected and cannot be edited. Enabling a parameter is required to edit 8000 and 9000 programs. It is absolutely critical you know what you are doing when working with 8000 and 9000 programs. Changing ...