Steady Green - Functioning normally
Blinking Green - Responding to locate function
Off - No power. Make sure adequate power is being supplied, 12 to 48vdc is supported. Try another power outlet, try another power adapter. If it still not working please contact Shop Floor Automations.
Blinking between Green & Red - Device is attempting to obtain an IP address from the DHCP server.
Steady Red (brief, <20 seconds) - Device is booting up.
Steady Red (sustained, >20 seconds) - Boot up failed, try rebooting unit. If this persists, contact Shop Floor Automations.
Blinking Red - IP conflict or DHCP server did not respond properly. Try to reboot the unit. If this persists, confirm the IP address is not in use or the DHCP server is functioning properly please contact Shop Floor Automations