Why are most Okuma MTConnect tags UNAVAILABLE
Problem
The MTConnect Agent on the Okuma control appears to be working, but most tags are UNAVAILABLE
Reason
Upon installation of the MTConnect Adapter, the Enable Monitoring Tags checkbox was not checked
Solution
- Open the MTConnect Adapter, go to the Configurations tab, check the Enable Monitoring Tags box; click SAVE & CLOSE when done
- If prompted for the username and password, use the following:
- Username: administrator
- Password: okuma+osp
Related Articles
How to Use Okuma SCOUT to Determine MTConnect Version & Compatibility
Overview This guide will take you through the steps to see if your P series Okuma CNC is compatible with MTConnect Requirements Setup a free Okuma Account (found at www.myokuma.com) SCOUT app (found at www.myokuma.com) USB Flash Drive Optional: USB ...
MTConnect Execution Values
The following are the values produced by the Execution tag. The values are shown in their standard form and only applicable to v1.3 or newer. READY The controller is ready to execute instructions. It is currently idle. ACTIVE The controller is ...
How to Check for MTConnect on Siemens 840D
Press Menu Select or Menu Function button Press far right softkey until you find a box at the bottom called "MTConnect" If the MTConnect button is shown, it's installed If it is not shown, it will need to be purchased from SFA and/or installed by a ...
How to back up a SQL Database
Overview Backing up a SQL database is useful when migrating SQL server, needing to send a copy of the database to someone, or simply backing up the database to restoration purposes. Requirements SQL Server Managment Studio SQL Credentials or Windows ...
Shop Floor Automations Downloads
Predator Software Predator DNC https://www.shopfloorautomations.com/predator-dnc/v11 Predator MDC https://www.shopfloorautomations.com/predator-mdc/v11 Predator PDM https://www.shopfloorautomations.com/predator-pdm/v11 Predator CNC Editor ...