Why does Predator DNC splits the file into DNC0, DNC1, etc?

Why does Predator DNC splits the file into DNC0, DNC1, etc?

Problem

Predator DNC is saving the uploaded (CNC to PC) program in multiple files. The first one is saved with the correct name, but does not have the entire program. The rest of the program is saved in the DNCX naming, e.g. 123.nc DNC0.nc DNC1.nc, when it should be all one file. Manual Receive from CNC works fine. 

Solution

The problem is the Remote Request Timeout in the Remote Request Link is too low. Increasing this value will allow for delays with hardware drivers, networking, and/or older machines. The default is "2000" milliseconds and should work fine. If you need to increase, try "5000" milliseconds. 


    • Related Articles

    • How do you do a remote request from Predator DNC?

      Remote request through Predator DNC: In many cases, a CNC machine may be located a good distance away from the computer, or perhaps a number of machines are connected to a central computer. In either case, the last thing you want is machine operators ...
    • Why am I getting “Too Many Active Commands” message in Predator DNC logs?

      Overview Predator DNC is trying to open more ports than you are licensed for. You either have too many machines configured or you have more then one PXP configuration file open. If you do have too many machines/commands configured, request an upgrade ...
    • Predator DNC Onsite Preparation

      Overview To help prepare for your onsite Predator DNC installation, it is recommended you read the following article. The technician will implement features detailed in the scope. Features such as drip-feed must be defined in the scope to be ...
    • Predator DNC Remote Installation Preparation

      Overview To help prepare for your remote Predator DNC installation, it is recommended you read the following Knowledge Base. Feel free to ask a SFA technician any questions. Licensing Preparation The Predator DNC application will use a temporary ...
    • How to Back Up the Predator DNC PXP Configuration

      Overview Backing up the Predator DNC configuration is key to preventing shop downtime. The Predator DNC configuration is known as the PXP. To back up the the PXP, use the following as a general guideline to find it and save to a secure location. Shop ...