Yasnac i80 RS-232 Parameters
Control
- Yasnac i80
Notate or take a picture of any parameters before you change them
Change Yasnac Parameters
- Press PROG key
- Press far right UP/DOWN softkey to select top row of softkeys (indicated by outlines)
- Press IN/OUT softkey
- Press RS232C softkey
- Change the following parameters in both IN and OUT columns
Changes are done by selecting the parameter and choosing the appropriate softkey- PORT to "NO. 2"
- UNIT to "RS232C"
- BPS to "9600"
- STOP BIT to "2BITS"
- PARITY to "EVEN"
- XON/XOFF to "ON"
- RTS CNTRL to "OFF"
- PARITY ISO to "OFF"
Related Articles
Haas RS-232 Parameters
Controls Any Haas with a RS-232 Port (usually 2016 or older, formally called Classic Haas Control or CHC) Notate or take a picture of any parameters before you change them Set Parameters Standard Transfers (Default) Press SETNG GRAPH button Press ...
Fanuc 0 RS-232 Parameters
Controls Fanuc 0M, 0T Notate or take a picture of any parameters before you change them Change Fanuc Parameters Put control in MDI mode Press DGNOS PARAM button until you see "PARAMETER" page Press PARAM softkey On SETTING 1 page, change the ...
Siemens 802D RS-232 Parameters
Controls Siemens 802D Notate or take a picture of any parameters before you change them Change Siemens 802D Parameters Press Menu Select button Press Services softkey Press Devices softkey Select Standard interface from top Press Copy to clipboard ...
Okuma OSP P100, P200, P300 RS-232 Parameters
Controls OSP-P100L, OSP-P100M OSP-P200L, OSP-P200M, OSP-P200S, OSP-P200LA, OSP-P200MA, OSP-P200SA OSP-P300L, OSP-P300M, OSP-P300S, OSP-P300LA, OSP-P300MA, OSP-P300SA Notate or take a picture of any parameters before you change them Set Tape Puncher ...
Siemens 810D Powerline RS-232 Parameters
Controls Siemens 810D Powerline Notate or take a picture of any parameters before you change them Change Siemens 802D Parameters Press MENU SELECT button Press SERVICES Press SET Set the following parameters Interface to “COM1” Protocol to “XON/XOFF” ...