This article is for USB and/or LAN Connect hardware and includes settings, parameters, and instructions to communicate to Mazak Mazatrol T Plus controls.
Controls
Mazatrol T Plus
Notate or take a picture of any parameters before you change them
Connections
Physically connect the USB/LAN Connect to the Fanuc control
Connect black 8-pin cable to bottom of the USB/LAN Connect
Connect tan 25-pin adapter to black 8-pin cable on the other end
Connect gray 4-pin cable from screen into board (if using internal USB/LAN Connect)
Remove yellow and silver gender changer from tan 25-pin adapter; plug into machine serial port
Attach USB stick or SD card to unit
Plug the power supply into the USB/LAN Connect
Screen should come on once powered
EIA Programs
All models of USB and/or LAN Connect support transferring of EIA programs.
Parameters and Settings
USB/LAN Connect Settings
USB/LAN Connect has three buttons, left, middle, and right. Depending on the screen, these can either be softkeys that reference a digital button on the screen or up (left), down (right), and select (middle) buttons.
Press Setup from the main menu
Press Baud Rate
Select "9600"
Press Data/Par/Stp (Data/Parity/Stop bits)
Select "7, even, 2"
Press Flow Control
Select "SW XON/XOFF"
Press EOB Delay (End-of-block delay)
Select "No Delay"
Press EOB Char (End-of-block character)
Select "CR LF"
Press Start Tx (Transmission start character)
Select "None"
Press End Tx (Transmission end character)
Select "None"
Press Start Rx (Receive start character)
Select "Automatic"
Scroll down and press Okay
Mazak Parameters
Press far-left softkey
Press PARAM.
Set the following values per parameter:
I1
1
I11
1
I2
3
I13
0
I3
0
I14
0
I5
3
I15
0
I6
3
I16
0
I7
0
I24
0
I8
60
I10
1
Press OK
Sending and Receiving Programs
Send to CNC
From CNC Machine Control
Press far left softkey
Press PROGRAMsoftkey
Press PROGRAM FILEsoftkey
Press DATA I/Osoftkey
Press TAPE I/Osoftkey
Press ALL LOAD NC <- TAPE
Press START softkey
From USB/LAN Connect
Start at the main menu
Press USB to CNC on the USB Connect, or File to CNC on the USB LAN Connect
For USB LAN Connect only, choose USB Files (USB flash drive) or SD Files (FTP)
Find the program you want to send, then press the middle button
Press Start
Program will now be sent into the machine
Receive from CNC
From USB/LAN Connect
Start at the main menu
Press CNC to USB on the USB Connect, or CNC to File on the USB LAN Connect
For USB LAN Connect only, choose USB Files (USB flash drive) or SD Files (FTP)
Press Start
From Machine Control
Press far left softkey
Press PROGRAMsoftkey
Press PROGRAM FILEsoftkey
Press DATA I/Osoftkey
Press TAPE I/Osoftkey
Press PUNCH NC -> TAPE softkey
Type the work number
Press INPUT button
Press START softkey
Mazatrol Programs
Only "Mazak" models of USB and/or LAN Connect support transferring of Mazatrol programs.
Parameters and Settings
USB/LAN Connect Settings
USB/LAN Connect has three buttons, left, middle, and right. Depending on the screen, these can either be softkeys that reference a digital button on the screen or up (left), down (right), and select (middle) buttons.
Press Setup from the main menu
Press Baud Rate
Select "9600"
Press Data/Par/Stp (Data/Parity/Stop bits)
Select "8 data, no parity, 2 stop bit"
Press Flow Control
For older controls, set to "CMT Ver 1"
For newer controls, set to "CMT Ver 2"
If CMT Ver 1 doesn't work, try CMT Ver 2, and vice versa.
Press EOB Delay (End-of-block delay)
Select "No Delay"
Press EOB Char (End-of-block character)
Select "None/binary"
Press Start Tx (Transmission start character)
Select "None"
Press End Tx (Transmission end character)
Select "None"
Press Start Rx (Receive start character)
Select "Automatic"
Scroll down and press Okay
Mazak Parameters
Press far-left softkey
Press DATA I/O
Press CMT
Press PARAM.
Set BAUDRATE to "9600"
Sending and Receiving Programs
Send to CNC
From USB/LAN Connect
Start at the main menu
Press USB to CNC on the USB Connect, or File to CNC on the LAN Connect
Find the program you want to send, then press the middle button
Press Start
From CNC Machine Control
Press far left softkey
Press DATA I/O softkey
Press CMT softkey
Press LOAD CMT -> NC softkey
Type the work number
Press INPUT button
Press START softkey
Receive from CNC
From USB/LAN Connect
Start at the main menu
Press CNC to USB on the USB Connect, or CNC to File on the LAN Connect
Press Start
From CNC Machine Control
Press far left softkey
Press DATA I/O softkey
Press CMT softkey
Press SAVE NC -> CMT softkey
Type the work number
Press INPUT button
Press START softkey
Additional Resources
For general installation and operating instructions, refer to the appropriate guide for your hardware model.