Haas RS-232 Parameters

Haas RS-232 Parameters

Controls

  1. Any Haas with a RS-232 Port (usually 2016 or older, formally called Classic Haas Control or CHC)
Notate or take a picture of any parameters before you change them

Set Parameters

Standard Transfers (Default)

  1. Press SETNG GRAPH button
  2. Press Page Down button until you find “RS-232 Ports” or a similarly named page (varies by Haas model year)
  3. Set “Baud Rate Select” to "9600" (2400, 4800, 19200, 38400 may also be used)
  4. Set “Parity Select” to "Even"
  5. Set “Stop Bit” to "2"
  6. Set “Synchronization” to "DC Codes"
  7. Set “RS-232 Data Bits” to "7"
  8. Set “Leader to Punch” to "None"
  9. Set “EOB Pattern” to "CR LF"
  10. Set “Add Spaces RS232 Out” to "Off"

High-Speed Transfers

  1. Press “SETNG GRAPH” button
  2. Press “Page Down” until you find “RS-232 Ports” or a similarly named page (varies by Haas model year)
  3. Set “Baud Rate Select” to "115200" (any baud rate may be used with XMODEM transfers)
  4. Set “Parity Select” to "None"
  5. Set “Stop Bit” to "1"
  6. Set “Synchronization” to "XMODEM"
  7. Set “RS-232 Data Bits” to "8"
  8. Set “Leader to Punch” to "None"
  9. Set “EOB Pattern” to "CR LF"
  10. Set “Add Spaces RS232 Out” to "Off"

    • Related Articles

    • Siemens 802D RS-232 Parameters

      Controls Siemens 802D Notate or take a picture of any parameters before you change them Change Siemens 802D Parameters Press Menu Select button Press Services softkey Press Devices softkey Select Standard interface from top Press Copy to clipboard ...
    • Okuma OSP P100, P200, P300 RS-232 Parameters

      Controls OSP-P100L, OSP-P100M OSP-P200L, OSP-P200M, OSP-P200S, OSP-P200LA, OSP-P200MA, OSP-P200SA OSP-P300L, OSP-P300M, OSP-P300S, OSP-P300LA, OSP-P300MA, OSP-P300SA Notate or take a picture of any parameters before you change them Set Tape Puncher ...
    • Siemens 810D Powerline RS-232 Parameters

      Controls Siemens 810D Powerline Notate or take a picture of any parameters before you change them Change Siemens 802D Parameters Press MENU SELECT button Press SERVICES Press SET Set the following parameters Interface to “COM1” Protocol to “XON/XOFF” ...
    • Fadal CNC 88HS RS-232 Parameters

      Controls All Fadal Controls Notate or take a picture of any parameters before you change them Set Parameters Press MANUAL button until you see “ENTER NEXT COMMAND <” Type “SETP” and press ENTER button Press ENTER button to keep G-code style setting ...
    • Fanuc 10, 11, 12, & 15 RS-232 Parameters

      Controls Fanuc 10M, 10T, 11M, 11T, 12M, 12T, 15M, 15T Notate or take a picture of any parameters before you change them Change Fanuc Parameters Set write key to enable Put control in MDI mode Press far left softkey until you see SETTING softkey Press ...