Okuma OSP P100, P200, P300 RS-232 Parameters
Controls
- OSP-P100L, OSP-P100M
- OSP-P200L, OSP-P200M, OSP-P200S, OSP-P200LA, OSP-P200MA, OSP-P200SA
- OSP-P300L, OSP-P300M, OSP-P300S, OSP-P300LA, OSP-P300MA, OSP-P300SA
Notate or take a picture of any parameters before you change them
Set Tape Puncher Interface Parameters
- Ensure NC PANEL key is set to "UNLOCK"
- Press PARAMETER button
- Press DISPLAY CHANGE (F8)
- Go to OPTIONAL PARA:(TAPE PUNCHER INTERFACE)
- Press CLOSE (F8)
Page 1 of 4 - Tape Puncher Interface
To change a parameter, press MENU [*] (F1) or SET (F1)
Press page up and page down buttons to cycle between pages
Set or confirm the following parameters:
- Tape code set to "ISO"
- ISO/EIA Automatically during reading set to "do not
- Tape TV check set to "do not"
- Enter tape code in ISO set to "CRLF"
- Tape delimiting code set to "%"
- Special code set to "ALARM"
- Program operation file name punch set to "punch"
- Tape feed set to "FEED HOLES"
- Tape feed holes set to "1"
Page 2 of 4 - Tape Puncher Interface
- Skip this page
Page 3 of 4 - Tape Puncher Interface (Input/Verify Parameter)
Set or confirm the following parameters:
- Device name of program operation set to "CN1:"
- baud rate(bps) set to "1200", "2400", "4800", "9600", or "19200" (recommended)
- RS232C character set to "8 bit"
- RS232C parity bit set to "NON"
- RS232C stop bit set to "2"
- Ready waiting time set to "40"
- Flow control set to "DC CODE"
- The delay timer until the RS switches OFF set to "0"
- Designates the amount of RS OFF time set to "0"
- DC3 when read/verify finished set to "DOES"
Page 4 of 4 - Tape Puncher Interface (Output Parameter)
Set or confirm the following parameters:
- Device name of program operation set to "CN1:"
- baud rate(bps) set to "1200", "2400", "4800", "9600", or "19200" (recommended)
- RS232C character set to "8 bit"
- RS232C parity bit set to "NON"
- RS232C stop bit set to "2"
- Ready waiting time set to "40"
- Flow control set to "DC CODE"
- The delay timer until the RS switches OFF set to "0"
- Designates the amount of RS OFF time set to "0"
- DC2/DC4 at punch set to "DOES NOT"
Set Optional Read/Write Parameters
- Ensure NC PANEL key is set to "UNLOCK"
- Press PARAMETER button
- Press DISPLAY CHANGE (F8)
- Go to OPTIONAL PARA:(READ/WRITE)
- Press CLOSE (F8)
Page 1 of 1 - Read/Write
Set or confirm the following parameters:
- Device number(for parameter set) set to "CN1:"
- Tape delimiting code set to "%"
- RS232C stop bit set to "2"
- RS232C parity bit set to "NON"
- Baud rate(bps) set to "1200", "2400", "4800", "9600", or "19200" (recommended)
- Flow control set to "DC CODE"
- Ready waiting time set to "40"
- RS2322C character set to "8 bit"
Finalize Settings
- Reboot control
Related Articles
Okuma OSP 5000M-G, 5020M, 700M, 7000M RS-232 Parameters
Controls OSP5000M-G OSP5020M OSP700M OSP7000M Notate or take a picture of any parameters before you change them Change Okuma Parameters Ensure the NC PANEL key is set to "UNLOCK" Press PARAMETER button Press ITEM DOWN (F7) softkey until you get to ...
Okuma OSP 5000L-G, 5020, 5020L, 700L, 7000L RS-232 Parameters
Controls OSP5000L-G OSP5020 OSP5020L OSP700L OSP7000L Notate or take a picture of any parameters before you change them Change Okuma Parameters Ensure the NC PANEL key is set to "UNLOCK" Press PARAMETER button Press ITEM DOWN (F7) softkey until you ...
Haas RS-232 Parameters
Controls Any Haas with a RS-232 Port (usually 2016 or older, formally called Classic Haas Control or CHC) Notate or take a picture of any parameters before you change them Set Parameters Standard Transfers (Default) Press SETNG GRAPH button Press ...
Siemens 802D RS-232 Parameters
Controls Siemens 802D Notate or take a picture of any parameters before you change them Change Siemens 802D Parameters Press Menu Select button Press Services softkey Press Devices softkey Select Standard interface from top Press Copy to clipboard ...
Siemens 810D Powerline RS-232 Parameters
Controls Siemens 810D Powerline Notate or take a picture of any parameters before you change them Change Siemens 802D Parameters Press MENU SELECT button Press SERVICES Press SET Set the following parameters Interface to “COM1” Protocol to “XON/XOFF” ...