Mazak Mazatrol 640 RS-232 Parameters

Mazak Mazatrol 640 RS-232 Parameters

Controls

  1. Mazatrol 640T, 640M
  2. Mazatrol 640T, 640M Nexus
  3. PC-Fusion-CNC
Notate or take a picture of any parameters before you change them

Set EIA (TAPE) Parameters

  1. Press far-left softkey
  2. Press DATA I/O
  3. Press TAPE
  4. Press PARAM.
  5. Set BAUDRATE to "19200" (2400, 4800, 9600 may also be used)
  6. Set DATA BIT to "8"
  7. Set PARITY to "NONE"
  8. Set STOP BIT to "1"
  9. Set HAND SHAKE to "DC CONTROL"
  10. Set WAIT TIME to "5.0"
  11. Set FORMAT to "ASCII"
  12. Set SAME WNo. to "ALARM"
  13. Set PORT to "COM1"
  14. Press PARAM. to close
  15. Press PARAM. DETAIL
  16. Set the following TAP parameters:
    1. TAP1
      1
      TAP9
      76
      TAP17
      0
      TAP25
      00000000
      TAP2
      0
      TAP10
      13
      TAP18
      0
      TAP26
      00000001
      TAP3
      0
      TAP11
      109
      TAP19
      0
      TAP27
      00000000
      TAP4
      0
      TAP12
      122
      TAP20
      0
      TAP28
      00111010
      TAP5
      1
      TAP13
      91
      TAP21
      0
      TAP29
      10
      TAP6
      0
      TAP14
      70
      TAP22
      0
      TAP30
      30
      TAP7
      0
      TAP15
      0
      TAP23
      0
      TAP31
      5
      TAP8
      0
      TAP16
      0
      TAP24
      0
      TAP32
      0
  17. Press PARAM. DETAIL to close
While the Mazak control is set to 8 Data Bit, None Parity, & 1 Stop Bit, the computer or hardware sending the part program should be 7 Data Bit, Even Parity, & 2 Stop Bit






    • Related Articles

    • Haas RS-232 Parameters

      Controls Any Haas with a RS-232 Port (usually 2016 or older, formally called Classic Haas Control or CHC) Notate or take a picture of any parameters before you change them Set Parameters Standard Transfers (Default) Press SETNG GRAPH button Press ...
    • Siemens 802D RS-232 Parameters

      Controls Siemens 802D Notate or take a picture of any parameters before you change them Change Siemens 802D Parameters Press Menu Select button Press Services softkey Press Devices softkey Select Standard interface from top Press Copy to clipboard ...
    • Okuma OSP 5000M-G, 5020M, 700M, 7000M RS-232 Parameters

      Controls OSP5000M-G OSP5020M OSP700M OSP7000M Notate or take a picture of any parameters before you change them Change Okuma Parameters Ensure the NC PANEL key is set to "UNLOCK" Press PARAMETER button Press ITEM DOWN (F7) softkey until you get to ...
    • Okuma OSP P100, P200, P300 RS-232 Parameters

      Controls OSP-P100L, OSP-P100M OSP-P200L, OSP-P200M, OSP-P200S, OSP-P200LA, OSP-P200MA, OSP-P200SA OSP-P300L, OSP-P300M, OSP-P300S, OSP-P300LA, OSP-P300MA, OSP-P300SA Notate or take a picture of any parameters before you change them Set Tape Puncher ...
    • Siemens 810D Powerline RS-232 Parameters

      Controls Siemens 810D Powerline Notate or take a picture of any parameters before you change them Change Siemens 802D Parameters Press MENU SELECT button Press SERVICES Press SET Set the following parameters Interface to “COM1” Protocol to “XON/XOFF” ...