How to Identify a Haas Next Generation Control (NGC)

How to Identify a Haas Next Generation Control (NGC)

Overview

There are various ways to determine if your Haas has a Next Generation Controller (NGC).

Screen Design

Since the screen design is unique to the NGC, the screen design is the most reliable way to check if you have a Haas NGC. 
  1. This is as NGC Screen

  2. This is not a NGC Screen

The following sets of criteria are best combined to determine if you have a Haas NGC. 

Serial Number

If the serial number is greater than 1134349, its likely a NGC.

Manufacture Date

If the MFG date is newer than 2016, there is a chance its a NGC. 

Misc.

On the left side of the electrical cabinet, you will find a network port. IF this network port is NOT accompanied by a DB25 serial port, there is chance you have a Haas NGC. If you do not find a network port and/or only a DB25 serial port, its not a Haas NGC. 

If you are still unsure you have a Haas NGC, a SFA Technician can help. Please submit a ticket with the model, serial number, mfg. date, and if a network port is present. Remember, pictures are worth a thousand words and always welcome with your ticket submission. 
 



    • Related Articles

    • How to Check if Haas NGC Supports SMBv2 and NTLMv2

      Overview SMBv1 and NTLMv1 have long been disabled by IT departments. Newer Haas Next Generation Controls support SMBv2 and NTLMv2. The easiest way to check is by checking the Net Share settings page. Check for SMBv2 Support Press SETTING button Go to ...
    • How to Configure Haas NGC Network Settings

      Overview This will go over how to configure the wired Ethernet settings and Net Share on a Haas Next Generation Control. Configure Wired Connection settings Press SETTING button Go to Network tab Go to Wired Connection tab To set the following ...
    • How to Configure Haas NGC DPRNT

      Overview Haas with Next Generation Control (NGC) allows DRPNT, but not using the traditional RS232 port. You can export DPRNT statements using a TCP port or save it to a file. This is a common practice to collect probe data from the control. Set ...
    • How to Edit Haas 9000 Programs

      Overview By default, 9000 programs are protected and cannot be edited. Enabling a parameter is required to edit 9000 programs. It is absolutely critical you know what you are doing when working with 9000 programs. Changing or deleting a protected ...
    • Why does Haas Output Tool Offset?

      Problem When uploading a program from the CNC to the server, the program includes O999999 (TOOL OFFSET). This will cause a remote request program to fail because the program will exceed the maximum lines allowed. Reason A parameter is turned on ...