How to Save Haas Machine Data via RS232
Overview
This article will review how to save Settings, Macro Variables, Offsets, Parameters, etc. from a Haas Classic Control (CHC) via RS232.
Requirements
- Haas CHC already connected to PC via RS232
Procedure to Save Machine Data via RS232
- Go to List Programs
- Go to page you want to save such as Parameters or Offsets
- Get PC ready to receive data
- Press SEND RS232 button
- Data will be received on PC
Related Articles
Haas RS-232 Parameters
Controls Any Haas with a RS-232 Port (usually 2016 or older, formally called Classic Haas Control or CHC) Notate or take a picture of any parameters before you change them Set Parameters Standard Transfers (Default) Press SETNG GRAPH button Press ...
How to Configure Haas NGC DPRNT
Overview Haas with Next Generation Control (NGC) allows DRPNT, but not using the traditional RS232 port. You can export DPRNT statements using a TCP port or save it to a file. This is a common practice to collect probe data from the control. Set ...
Siemens 840D RS-232 Parameters
Controls Any Siemens SINUMERIK 840D w/ RS-232 Notate or take a picture of any parameters before you change them Set Parameters Press MENU SELECT button Press Services softkey Press Interface softkey Press RS232C softkey (on the right) to get to the ...
How to Locate Haas Spare 115vac Plugs
Overview Most Haas CNC machines have spare 115vac plugs that can be used for 115vac powered accessories. This article will help determine if your machine has them. Opening the electrical cabinet should only be performed by trained technicians. ...
How to Test a Haas Serial Port
Overview The Haas loopback test can be used to test the integrity of the serial port. This procedure was provided by Haas and is an official test. Preparation Change setting 14 to CTS/RTS On port 1 (top port), jump the following pins on the upper (or ...