Parameters - Haas Classic Control
Controls
- Any Haas with a RS-232 Port (usually 2016 or older, formally called Classic Haas Control or CHC)
Notate or take a picture of any parameters before you change them
Set Parameters
Standard Transfers (Default)
- Press SETNG GRAPH button
- Press Page Down button until you find “RS-232 Ports” or a similarly named page (varies by Haas model year)
- Set Baud Rate Select to "9600" (2400, 4800, 19200, 38400 may also be used)
- Set Parity Select to "Even"
- Set Stop Bit to "2"
- Set Synchronization to "DC Codes"
- Set RS-232 Data Bits to "7"
- Set Leader to Punch to "None"
- Set EOB Pattern to "CR LF"
- Set Add Spaces RS232 Out to "Off"
High-Speed Transfers
- Press SETNG GRAPH button
- Press Page Down until you find “RS-232 Ports” or a similarly named page (varies by Haas model year)
- Set Baud Rate Select to "115200" (any baud rate may be used with XMODEM transfers)
- Set Parity Select to "None"
- Set Stop Bit to "1"
- Set Synchronization to "XMODEM"
- Set RS-232 Data Bits to "8"
- Set Leader to Punch to "None"
- Set EOB Pattern to "CR LF"
- Set Add Spaces RS232 Out to "Off"