Siemens 810D Powerline RS-232 Parameters
Controls
- Siemens 810D Powerline
Notate or take a picture of any parameters before you change them
Change Siemens 802D Parameters
- Press MENU SELECT button
- Press SERVICES
- Press SET
- Set the following parameters
- Interface to “COM1”
- Protocol to “XON/XOFF”
- Baud Rate to “9600”
- Data Bits to “7”
- Parity to “even”
- Stop Bits to “2”
- XON (hex) to “17”
- XOFF (hex) to “19”
- End of transfer to “1a”
- Check “Stop with EOT character”
- Press Save Settings
Related Articles
Siemens 802D RS-232 Parameters
Controls Siemens 802D Notate or take a picture of any parameters before you change them Change Siemens 802D Parameters Press Menu Select button Press Services softkey Press Devices softkey Select Standard interface from top Press Copy to clipboard ...
Haas RS-232 Parameters
Controls Any Haas with a RS-232 Port (usually 2016 or older, formally called Classic Haas Control or CHC) Notate or take a picture of any parameters before you change them Set Parameters Standard Transfers (Default) Press SETNG GRAPH button Press ...
Siemens 840D RS-232 Parameters
Controls Any Siemens SINUMERIK 840D w/ RS-232 Notate or take a picture of any parameters before you change them Set Parameters Press MENU SELECT button Press Services softkey Press Interface softkey Press RS232C softkey (on the right) to get to the ...
Okuma OSP P100, P200, P300 RS-232 Parameters
Controls OSP-P100L, OSP-P100M OSP-P200L, OSP-P200M, OSP-P200S, OSP-P200LA, OSP-P200MA, OSP-P200SA OSP-P300L, OSP-P300M, OSP-P300S, OSP-P300LA, OSP-P300MA, OSP-P300SA Notate or take a picture of any parameters before you change them Set Tape Puncher ...
Fadal CNC 88HS RS-232 Parameters
Controls All Fadal Controls Notate or take a picture of any parameters before you change them Set Parameters Press MANUAL button until you see “ENTER NEXT COMMAND <” Type “SETP” and press ENTER button Press ENTER button to keep G-code style setting ...